A temperature and humidity sensor is the smallest part of a monitoring system and the part that decides whether the numbers can be trusted. This page explains the sensor types HHET fits as part of its wider temperature and humidity monitoring service, what accuracy and calibration actually mean, and how to choose between them for a cold room, a truck or a warehouse.
Sensor types: wireless, wired, probe, industrial
Most sensors share the same two measuring elements: a temperature element, usually a thermistor or a platinum resistance element, and, for humidity, a capacitive element whose electrical behaviour changes as moisture is absorbed. The differences are in the housing, the connection and what environment each can survive.
| Type | How it connects | Good for | Watch out for |
|---|---|---|---|
| Wireless sensor with internal element | Radio to a gateway | Rooms, shelves, offices, stores | Radio range through steel and thick insulation |
| Wireless sensor with external probe | Radio, probe on a lead | Fridges, freezers, incubators | Lead routing through door seals |
| Wired sensor | Cable to a controller or gateway | Fixed plant, places with poor radio | Installation time, cable damage |
| Industrial transmitter | 4-20 mA, RS-485 or similar output | Plant rooms, process areas, building systems | Needs a compatible input and power supply |
| Vehicle-mounted sensor | Cable to an in-vehicle unit | Refrigerated trucks and vans | Placement in the load space, vibration |
The usual choice in a Saudi site is wireless, because it avoids cutting into walls and can be moved. Wired and industrial types are chosen where the environment demands it, or where the sensor must feed an existing control system. How data moves from sensor to dashboard, including LoRa, cellular and Wi-Fi options, is covered on the page about IoT and wireless monitoring.
Accuracy and calibration
Accuracy is how close a reading is to the true value; a data sheet usually states it as plus or minus a figure over a stated range. Two traps are worth knowing. First, humidity accuracy is usually quoted for a limited range and is much poorer at the extremes. Second, a sensor that is accurate when it leaves the factory drifts over time, humidity elements especially, which is why calibration exists.
Calibration compares the sensor with a reference of known accuracy at one or more points and records the difference. A certificate shows what was tested, against what reference, and when. For pharmaceutical and laboratory use, documented calibration at a defined interval, often annual, is commonly expected; for general food and warehouse use it is good practice. HHET specifies the calibration requirement per application and confirms what it can supply before quoting. It does not claim certification it cannot show, and for regulated storage, see the notes on SFDA temperature monitoring.
Resolution is not accuracy. A display that shows 0.1 degrees does not mean the reading is right to 0.1. Read the accuracy line on the data sheet, and for humidity, check the range it applies to.
- Placement error. A perfectly calibrated sensor in direct sun, by a vent or beside a door still reports the wrong environment.
- Response time. A sensor in a buffered holder responds slowly on purpose; a bare sensor reacts quickly but shows noise.
- Drift check. Compare a sensor against a reference occasionally, and replace or recalibrate when the gap exceeds your tolerance.
Choosing a sensor for cold rooms, trucks and warehouses
The environment decides the sensor, not the other way round. In a cold room you need a probe rated for the lowest temperature, a body that tolerates condensation, and a radio path that survives insulated panels. On a refrigerated truck, vibration, repeated door openings and a cab-to-body cable run matter more; the vehicle side is explained under refrigerated truck monitoring. In a warehouse, the question is how many sensors, at which heights and where; the answer comes from the building, and a mapping exercise helps, as described on the warehouse monitoring page.
- Range. Check that the whole temperature and humidity range you will meet is inside the rated range.
- Environment. Condensation, washdown, dust and heat call for different housing ratings.
- Reporting interval and battery. Faster reporting shortens battery life; choose the interval that matches how quickly a problem becomes serious.
- Calibration. Decide whether you need certificates, and how often.
- Alert behaviour. Check that the sensor keeps logging when the connection fails.
Jeddah conditions deserve a specific mention. Coastal humidity is high for much of the year, outdoor units sit in direct sun and summer temperatures push sensor housings beyond what a standard indoor unit was designed for. State the real operating environment when you ask for a quotation.
Common mistakes we see
The first is using a sensor outside its rated range, for example a room sensor in a freezer, which reads wrongly or fails silently. The second is a single sensor for a large space, where it reports a comfortable average while one corner is out of range. The third is ignoring the battery: a sensor reporting every minute needs far more attention than one reporting every fifteen. The fourth is forgetting that humidity sensors age faster than temperature elements. A system with good alerts and neglected sensors gives false comfort, so the maintenance plan, including checks, calibration and battery replacement, belongs in the specification from the start, not as an afterthought after the first failure.
Sensor pricing model
HHET does not publish sensor prices because the right answer depends on the setup. What drives the cost is worth knowing, so you can compare quotes properly:
- The sensor type, range and probe, and whether calibration certificates are included.
- The number of monitoring points, and the gateways needed to cover them.
- Installation work, including cable routing, mounting and commissioning.
- Platform access and alerts, which may be charged per sensor or per site, depending on the plan agreed.
- Recalibration or replacement at intervals, if your application requires it.
Ask every supplier the same questions: what is the stated accuracy, over what range, what happens to data during an outage, and what recurring costs follow the first purchase. Two quotes are only comparable if they answer these in the same way. The guide on how to choose a data logger covers the same questions for stand-alone devices.
To get a quotation, request a quote and describe the rooms or vehicles, the temperature range, and whether you need calibration certificates. A site visit or photographs let HHET specify the right sensor type for each point.

Last reviewed .